Measuring Transformer

Measuring Transformer2018-05-22T10:02:32+00:00

14-12-16---VDC08A-Images-Finished-(3)VDC 50/600 Ohm Low Power Wide Band Measuring Transformers – Wide band operation models for:

  • 20Hz – 20kHz
  • 100Hz – 200kHz
  • 50kHz – 10MHz
  • 1.5MHz – 32MHz
  • 1 Watt Average
  • 2 Watts PEP
  • Fully encapsulated

The Minns Baluns VDC Series are designed for precision measurement purposes where 50/600 Ohm transformation is required with low VSWR and high balance ratio.

All the measuring transformers are fully encapsulated within a cast aluminium case to provide a high stability product capable of withstanding the most severe environment.

 


 

Balanced Impedance (Ohm)      
Standard frequency rangesBalanced terminalsBalance ratioVSWRBNC'N'UHF'
20Hz - 20kHzCeramic M6>12dB1.1 : 1VDC08AVDC08BVDC08C
100Hz - 200kHzCeramic M6>50dB1.1 : 1VDC05AVDC05FVDC05G
50kHz - 10MHzCeramic M6>40dB1.1 : 1VDC06AVDC06FVDC06G
1.5MHz - 32MHzCeramic M6>26dB1.1 : 1VDC02BVDC02AVDC02C
Technical Specs. 
Frequency rangeSee table above
Unbalanced impedance:50 Ohms
Balanced impedance:600 Ohms
Power rating:+10dBm
Insertion loss:Less than 0.2 dB
VSWR:See table above
Balance ratio:See table above
Balance connection:M6 insulators
Unbalanced connection:See table above
Temperature range:-20ºC to +55ºC